Overview
The hydrometer is an instrument which is constructed on the Archimedes principle that a solid body displaces its own weight of the liquid in which it floats. Hydrometers can be divided into two general classes; namely for liquid heavier than water and for liquids lighter than water.
Alcohol Hydrometers - Tralle and Proof Scales -
Verify the alcohol content of distilled spirits
Both models include the same ranges; model 6612-2TS also features an internal thermometer with SafetyBLUE
fill for measuring solution temperature from -10 to +100°F.
- Calibrated for use at 15°C/60°F
Alcohol Hydrometers - Proof Scale, Internal Revenue Service Spec-
Verify the alcohol content of your ethyl alcohol-based spirits with these hydrometers
- Tolerances match those laid out by the Internal Revenue Service specifications
- Calibrated for use at 15°C/60°F
Alcohol Hydrometers w/3-point NIST Certificate and PVC Case- Proof Scale, Internal Revenue Service Specification-
Verify the alcohol content of your ethyl alcohol-based spirits with these hydrometers
Tolerances match those laid out by the Internal Revenue Service specifications.
- Commonly used in distilleries requiring certification
- Calibrated for use at 15°C/60°F
INCLUDES: Hydrometer, NIST-traceable certificate with 3 data points, and a protective PVC case
Specifications
Alcohol Hydrometers - Tralle and Proof Scales
Item No. |
Tralle Range |
Proof Range |
Internal Thermometer Included |
Length |
6612-1 |
0 to 100% |
0 to 200% |
No |
12 in. (305 mm) |
6612-2TS |
0 to 100% |
0 to 200% |
Yes |
14 in. (355 mm) |
Alcohol Hydrometers - Proof Scale, Internal Revenue Service Spec
Item No. |
Proof Range |
Subdivision |
Tolerenace |
Internal Revenue Size |
Length |
6613-B |
80 to 120% |
0.5% |
±0.5% |
B |
9.1 in. (230 mm) |
6613-F |
0 to 20% |
0.2% |
±0.3% |
F |
12 in. (305 mm) |
6613-G |
20 to 40% |
0.2% |
±0.4% |
G |
12 in. (305 mm) |
6613-H |
40 to 60% |
0.2% |
±0.4% |
H |
12 in. (305 mm) |
6613-I |
60 to 80% |
0.2% |
±0.3% |
I |
12 in. (305 mm) |
6613-K |
75 to 95% |
0.2% |
±0.3% |
K |
12 in. (305 mm) |
6613-L |
90 to 110% |
0.2% |
±0.3% |
L |
12 in. (305 mm) |
6613-M |
105 to 125% |
0.2% |
±0.3% |
M |
12 in. (305 mm) |
6613-N |
125 to 145% |
0.2% |
±0.3% |
N |
12 in. (305 mm) |
6613-P |
145 to 165% |
0.2% |
±0.3% |
P |
12 in. (305 mm) |
6613-Q |
165 to 185% |
0.2% |
±0.2% |
Q |
12 in. (305 mm) |
6613-R |
185 to 206% |
0.2% |
±0.2% |
R |
12 in. (305 mm) |
Alcohol Hydrometers w/3-point NIST Certificate and PVC Case- Proof Scale, Internal Revenue Service Specification
Item No. |
Proof Range |
Subdivision |
Tolerance |
I.R. Size |
Length |
6613-B-C |
80 to 120% |
0.5% |
±0.5% |
B |
9.1 in. (230 mm) |
6613-F-C |
0 to 20% |
0.2% |
±0.3% |
F |
12 in. (305 mm) |
6613-G-C |
20 to 40% |
0.2% |
±0.4% |
G |
12 in. (305 mm) |
6613-H-C |
40 to 60% |
0.2% |
±0.4% |
H |
12 in. (305 mm) |
6613-I-C |
60 to 80% |
0.2% |
±0.3% |
I |
12 in. (305 mm) |
6613-K-C |
75 to 95% |
0.2% |
±0.3% |
K |
12 in. (305 mm) |
6613-L-C |
90 to 110% |
0.2% |
±0.3% |
L |
12 in. (305 mm) |
6613-M-C |
105 to 125% |
0.2% |
±0.3% |
M |
12 in. (305 mm) |
6613-N-C |
125 to 145% |
0.2% |
±0.3% |
N |
12 in. (305 mm) |
6613-P-C |
145 to 165% |
0.2% |
±0.3% |
P |
12 in. (305 mm) |
6613-Q-C |
165 to 185% |
0.2% |
±0.2% |
Q |
12 in. (305 mm) |
6613-R-C |
185 to 206% |
0.2% |
±0.2% |
R |